|
Comparison of Magnetic Resonance Angiography and Standard Angiography in Diagnosing Atherosclerosis Clinical Trials References presented on Clinical Trials Search is not intended to be a substitute for proven healthcare advice, trips or professional assistance by using a real medical. We aren't mDs. Always confer with your physician about Comparison of Magnetic Resonance Angiography and Standard Angiography in Diagnosing Atherosclerosis conditions. Clinical Trials Search.org is a website devoted to listing clinical research studies in human subjects. Comparison of Magnetic Resonance Angiography and Standard Angiography in Diagnosing Atherosclerosis Clinical research trials and Comparison of Magnetic Resonance Angiography and Standard Angiography in Diagnosing Atherosclerosis medical trials take place in hundreds of localities across the U.S.. A clinical trial or clinical study is a research project with human volunteer subjects. Clinical drug trials and pharmaceutical clinical trials usually evaluate the effectualness of new does drugs. The purpose of the studies / projects is to solve specific human health questions. Clinical trials are a popular way for physicians, government agencies, and private sector companies to discover treatments for all sorts of conditions, such as Comparison of Magnetic Resonance Angiography and Standard Angiography in Diagnosing Atherosclerosis. Comparison of Magnetic Resonance Angiography and Standard Angiography in Diagnosing Atherosclerosis Clinical Trials and other clinical trials permit volunteers to access healthcare treatment choices before they are available to the general public. Some times the subjects recieve professional assistance for without cost, and every now and again they are compensated for their time. Sometimes there is a cost for a Comparison of Magnetic Resonance Angiography and Standard Angiography in Diagnosing Atherosclerosis clinical trial. Subjects often receive the most expert healthcare possible for their Comparison of Magnetic Resonance Angiography and Standard Angiography in Diagnosing Atherosclerosis condition. Risks are a reality, nevertheless, and could include additional or frequent dr. calls, healthcare dangers (perhaps life-jeopardising), and/or the treatment being ineffective. Trials are federally governed with stern guidelines to protect clinical trials subjects.
|
|
|
|
|
|
|
Home > "C" Clinical Trials Conditions > Comparison of Magnetic Resonance Angiography and Standard Angiography in Diagnosing Atherosclerosis Comparison of Magnetic Resonance Angiography and Standard Angiography in Diagnosing Atherosclerosis
Comparison of Magnetic Resonance Angiography and Standard Angiography in Diagnosing Atherosclerosis
For Condition: Atherosclerosis
Status: Completed
Sponsor(s): Warren G Magnuson Clinical Center (CC) ,
Synopsis: This study will evaluate ways to improve magnetic resonance angiography (MRA) for diagnosing atherosclerosis (hardening and narrowing of the arteries). MRA is a new method for looking at arteries and veins without standard angiography, which requires inserting a catheter into a blood vessel, injecting a contrast material, and obtaining X-ray images. Current MRA techniques, however, do not depict the lumen (cavity) of small vessels well enough to accurately determine the extent of their narrowing. This study will test image processing methods with the eventual goal of improving MRA accuracy to the point that it can replace X-ray catheter angiography for diagnosing atherosclerotic disease. Patients with atherosclerosis who have had conventional angiography at Suburban Hospital in Bethesda, MD, may be considered for this study. They will be screened with a brief history and physical examination, and those enrolled will have a MRA scan within 72 hours of their conventional angiogram. For this procedure, a catheter is placed in a vein in the patient's arm and the patient lies on a table that slides into a magnetic resonance imaging (MRI) scanner-a large donut-shaped machine with a magnetic field. Surface coils-flexible, padded antennae used to improve the quality of the pictures-are wrapped around the patient's legs. At times during the scan, the patient is asked to hold his or her breath for several seconds, and a contrast material called gadolinium is injected through the catheter in the vein. This substance enhances the images of blood flow in the vessels. The procedure generally takes about an hour and a half, although the actual imaging takes only a small part of that time.
Details: Contrast Enhanced Magnetic Resonance Angiography (MRA) is a developing technology for the non-invasive evaluation of arterial and venous structures which does not require x-ray based catheter angiography. While dramatic progress in MRA has recently been made, there are still substantial limitations in the accuracy of MRA in grading stenoses and detecting small accessory vessels. The purpose of this study is to recruit patients with documented atherosclerotic disease as confirmed on catheter angiography performed at Suburban Hospital for evaluation with state-of-the-art MRA on MRI units, also at Suburban Hospital. We intend to test new surface coils, new pulse sequence designs, and advanced image processing algorithms in order to improve MRA accuracy to the point that a large-scale study of MRA vs. conventional angiography is possible. The goal of this pilot study is to improve MRA to the point that it can reliably replace diagnostic x-ray catheter angiography in the evaluation of patients with atherosclerotic disease.
Eligibility:
Study Type: Interventional, Treatment, Safety
Minimum Age/Maximum Age: /
Genders: Both
Protocol Entry Criteria: Patient must be willing to participate in the study. Patient must have documented atherosclerotic disease of an extracranial vessel by angiography performed within 72 hours of the MRA. Patient must be referred by a physician who is caring for the patient and to whom the results will be provided. Patient must be clinically stable and be judged by their physician able to tolerate lying in the MR gantry for up to 1.5 hours. Patient must have serum Creatinine value less than 3.0mg/dl. Must not have any contraindication for MRI including: pacemaker or other implanted electronic device; cochlear implants; metal in the eye; embedded shrapnel fragments; cerebral aneurysm clips; or medical Infusion pumps. Must not have an allergy to Gadolinium based contrast media. Must not have unsatisfactory performance status as judged by the referring physician such that the patient could not tolerate an MRI scan for 1.5 hours. Examples of medical conditions that would not be accepted would include unstable angina, dyspnea at rest, severe pain at rest, and severe back pain. Must not have intercurrent illness that requires treatment that would be jeopardized by the MRA scan. Subjects must not require sedation for MRI studies other than administered normally for a conventional angiogram. Must not be pregnant. Must not be nursing mothers.
Total Enrollment: 40
Location and Contact Information:
Warren G. Magnuson Clinical Center (CC)
Bethesda, Maryland, 20892
United States
Additional Information:
Study ID Numbers: 000028; 00-CC-0028
Study Start Date: December 8, 1999
Record last reviewed: September 7, 2002
Additional information available at: clinicaltrials.gov
Clinicaltrials.gov Reference link: NCT00001946
Other Atherosclerosis Studies:
1. A blinded study conducted at multiple centers evaluating various doses of an investigational agent (BO-653) against placebo, for safety and effectiveness in preventing post-angioplasty blood vessel re-closure (restenosis) in stented vessels.
2. Cholesterol Reduction in Seniors Program (CRISP)
3. Natural History of Peripheral Arterial Disease
4. Non-Traditional Cardiovascular Risk Factors in Type 2 Diabetes Mellitus - Ancillary to VA Study of Glycemic Control
5. Antioxidants and Prevention of Early Atherosclerosis
Related Studies:
Other Atherosclerosis Clinical Trials
Other Maryland Clinical Trials
Other Bethesda Clinical Trials
Comparison of Magnetic Resonance Angiography and Standard Angiography in Diagnosing Atherosclerosis
|
|
|
|
|
|
|
|